D-Luciferin (D-(-)-Luciferin) sodium is the substrate of luciferases that catalyze the production of light in bioluminescent insects[1].
体外研究 (In Vitro)
D-luciferin is the natural substrate of the enzyme luciferase (Luc), that catalyzes the production of the typical yellowgreen light of fireflies.The present review covers the synthesis of D-luciferin and derivatives or analogues that are substrates or inhibitors of the luciferase from the American firefly Photinus pyralis, the enzyme more frequently used in techniques of in vitro and optical imaging[1]. D-Luciferin exhibits a decrease in the measured Km in PC3M-Luc cell lysates with a Km of 34 μM[2].
MCE has not independently confirmed the accuracy of these methods. They are for reference only.
体内研究 (In Vivo)
Bioluminescence imaging (BLI) using the firefly luciferase (Fluc) as a reporter gene and D-luciferin as a substrate is currently the most widely employed technique. The total signal intensity is plotted against the time after D-luciferin injection to generate a time-intensity curve. In addition to the peak signal, the signals at fixed time points (5, 10, 15, and 20 min) after D-luciferin injection are determined as alternatives to the peak signal. The signal in a given time-intensity curve is normalized for the peak signal in the curve to represent the pattern of temporal changes after D-luciferin injection[3]. Inject with 10 μL of D-luciferin (intraperitoneally or intravenously) stock solution per gram of body weight: normally ~200 μL for a 20 g mouse for a standard 150 mg/kg injection. Thaw D-Luciferin (either Potassium or Sodium Salt) at room temperature and dissolve in dPBS (no calcium or magnesium) to a final concentration of 15 mg/mL. Pre-wet a 0.22 μm filter by drawing through 5-10 mL of sterile H2O and discard water. Sterilize the D-Luciferin solution through the prepared 0.22 μm syringe filter.
MCE has not independently confirmed the accuracy of these methods. They are for reference only.
分子量
302.30
Formula
C11H7N2NaO3S2
CAS 号
103404-75-7
中文名称
D-萤光素钠盐
运输条件
Room temperature in continental US; may vary elsewhere.
储存方式
4deg;C, sealed storage, away from moisture and light
*In solvent : -80deg;C, 6 months; -20deg;C, 1 month (sealed storage, away from moisture and light)
溶解性数据
In Vitro:;
H2O : 250 mg/mL (826.99 mM; Need ultrasonic)
DMSO : 100 mg/mL (330.80 mM; Need ultrasonic)
配制储备液
浓度溶剂体积质量
1 mg
5 mg
10 mg
1 mM
3.3080 mL
16.5399 mL
33.0797 mL
5 mM
0.6616 mL
3.3080 mL
6.6159 mL
10 mM
0.3308 mL
1.6540 mL
3.3080 mL
*
请根据产品在不同溶剂中的溶解度选择合适的溶剂配制储备液;一旦配成溶液,请分装保存,避免反复冻融造成的产品失效。 储备液的保存方式和期限:-80°C, 6 months; -20°C, 1 month (sealed storage, away from moisture and light)。-80°C 储存时,请在 6 个月内使用,-20°C 储存时,请在 1 个月内使用。
In Vivo:
请根据您的实验动物和给药方式选择适当的溶解方案。以下溶解方案都请先按照 In Vitro 方式配制澄清的储备液,再依次添加助溶剂:
将 2 g 磺丁基醚 β-环糊精加入 5 mL 生理盐水中,再用生理盐水定容至 10 mL,完全溶解,澄清透明
*以上所有助溶剂都可在 MCE 网站选购。
参考文献
[1]. Giuseppe Meroni, et al. D-Luciferin, derivatives and analogues: synthesis and in vitro/in vivo luciferase-catalyzed bioluminescent activity. ARKIVOC 2009 (i) 265-288.
[2]. Rajesh Shinde, et al. Luciferin derivatives for enhanced in vitro and in vivo bioluminescence assays. Biochemistry. 2006 Sep 19;45(37):11103-12.
[3]. Inoue Y, et al. Timing of imaging after d-luciferin injection affects the longitudinal assessment of tumor growthusing in vivo bioluminescence imaging. Int J Biomed Imaging. 2010;2010:471408.
Animal Administration [3]
Mice[3] In vivo BLI is performed using a cooled charge-coupled device camera system (IVIS Imaging System 100) 3, 5, 7, 10, 12, 14, 19, 21, 24, and 28 days after the inoculation of HCT116-Luc cells. Mice are injected with 75 mg/kg D-luciferin in 100 μL of phosphate-buffered saline subcutaneously near the scapula and were placed in the light-tight chamber of the imaging system. Beginning 5 min after injection, dorsal luminescent images with an exposure time of 1 s are acquired sequentially at a rate of one image per min until 20 min after D-luciferin injection. Data acquisition is continued until 40 min postinjection on days 3 or 5 and until 25 min on day 7, because of the prolonged time course of light emission. Binning is 4 and the field of view is 15 cm.
MCE has not independently confirmed the accuracy of these methods. They are for reference only.
参考文献
[1]. Giuseppe Meroni, et al. D-Luciferin, derivatives and analogues: synthesis and in vitro/in vivo luciferase-catalyzed bioluminescent activity. ARKIVOC 2009 (i) 265-288.
[2]. Rajesh Shinde, et al. Luciferin derivatives for enhanced in vitro and in vivo bioluminescence assays. Biochemistry. 2006 Sep 19;45(37):11103-12.
[3]. Inoue Y, et al. Timing of imaging after d-luciferin injection affects the longitudinal assessment of tumor growthusing in vivo bioluminescence imaging. Int J Biomed Imaging. 2010;2010:471408.