millipore除 菌过滤器MPGL1GCA3
millipore除 菌过滤器MPGL1GCA3 Sterile Millipak®-100 Filter Unit 0.22µm 9/16in. HB/HB millipore除 菌过滤器MPGL1GCA3 0.22 µm
millipore除 菌过滤器MPGL1GCA3
Description | |
---|---|
Catalogue Number | MPGL1GCA3 |
Trade Name |
|
Description | Sterile Millipak®-100 Filter Unit 0.22µm 9/16in. HB/HB |
Product Information | |
---|---|
Device Configuration | Gamma Gold Capsule |
Connections, Inlet/Outlet | 14mm (9/16in.) Hose Barb |
Maximum Differential Pressure, bar (psid) | Forward: 4.1 bar (60 psid) @ 25°C; 1.7 bar (25 psid) @ 80°C; 0.35 bar (5 psid) @ 123°C; Reverse: 0.7 bar (10 psid) @ 25°C |
Maximum Inlet Pressure, bar (psi) | 5.2 bar (75 psi) @ 25°C |
Good Manufacturing Practices | These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices. |
Biological Information | |
---|---|
Bacterial Endotoxins | Aqueous extraction contains ≤0.5EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test |
Media | Durapore® |
Sterility | Sterile |
Sterilization | 3 autoclave cycles of 90min @ 123°C; not in-line steam sterilizable |
Bacterial Retention | Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷CFU/cm² using ASTM®F838 methodology. |
Wettability | Hydrophilic |
Physicochemical Information | |
---|---|
Pore Size | 0.22 µm |
Inlet Connection | Hose Barb |
Outlet Connection | Hose Barb |
Bubble Point at 23°C | ≥3450mbar (50psig) air with water |
Flow Rate | 11 L/min @ 2.8bar ΔP |
Gravimetric Extractables | The extractables level was equal to or less than 2.5mg per sterilized device after a 200mL flush and 24hours in water at controlled room temperature. |
Non-Fiber Releasing | This product was manufactured with a Durapore® membrane which meets the criteria for a “non-fiber releasing” filter as defined in 21CFR210.3(b)(6). |
USP Bacterial Endotoxins | A sample aqueous extraction contains less than 0.5EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test. |
Dimensions | |
---|---|
Filtration Area | 500 cm² |
Process Volume | 50 L |
Inlet Connection Diameter | 9/16 in. |
Outlet Connection Diameter | 9/16 in. |
Materials Information | |
---|---|
Chemistry |
|
Device Material |
|
Support Material | Polycarbonate |
Vent Cap Material | Polyvinylidene fluoride (PVDF) |
Packaging Information | |
---|---|
Material Size | 3 |
Material Package | Blister |
Specifications | |
---|---|